Model No. |
UXM-30LX-EW |
Power source |
DC10 to 30V |
Light source |
Laser diode (λ = 905nm) Class 1 (FDA) |
Supply Current |
Regular current: DC10V(<600mA), DC12V(<600mA), DC24V(<250mA)
Start-up current: DC10V(<2A), DC12V(<1.5A), DC24V(<0.75A) |
Power consumption |
<6W (regular) |
Detection range & Detectable width |
Assured detection: 0.1 to 30m*2, Max. detectable distance: 100m (limitation of data output)
Black(diffuse reflectance 10%), 500 mm × 500 mm
Min. detectable width: φ65mm (5m), φ130mm(10m), φ400mm(30m) |
Accuracy |
Under 3,000lx : ±50mm*1 (Black diffuse reflectance 10% at 10m, White Kent Sheet at 30m)
Under 100,000lx : ±100mm*1 (Black diffuse reflectance 10% at 10m, White Kent Sheet at 30m) |
Measurement resolution & Repeated accuracy |
1mm
Under 3,000lx : σ<50mm (Black diffuse reflectance 10% up to 10m, White Kent Sheet up to 30m)
Under 100,000lx : σ<100 mm (Black diffuse reflectance 10% up to 10m, White Kent Sheet up to 30m) |
Scanning angle |
190° |
Angular resolution |
0.25°(360°/1440) |
Scanning speed |
50ms (Motor speed : 1200rpm) |
Interface |
Ethernet 100BASE-TX (Auto-negotiation) |
Output signal |
2 Output signal: Error output, Synchronous output |
Indication light |
Power (Green),
Operation/Error (Orange) : Operating (ON), Error (blink) |
Ambient condition
(Temperature, Humidity) |
Operating: -10 to +50 degrees C
85%RH (Without condensation and frost) |
Environmental resistance |
Measured distance will be shorter than actual distance under rain, snow and direct sunlight working environment*2 |
Vibration resistance |
10 to 55Hz double amplitude of 1.5mm in X,Y,Z direction for 2 hrs.
55 to 200Hz, 19.6 m/s2 sweep 2 min,
in X, Y, Z direction , 1hr for each direction |
Shock resistance |
196m/s2 10 times each in X, Y, Z directions |
Protection structure |
IP67 |
Insulation resistance |
10MΩ |
Weight |
800g |
Casing material |
Front casing & optical window: Polycarbonate
Rear casing: Aluminum |
Dimensions(W×D×H) |
124mm×126mm×150mm (excluding connector) |
*1 Measurement under direct interference light is not assured (Sunlight etc.).
*2 Please verify the actual performance of the sensor under the intended working environment conditions